Skip to main content

mantaroof.com

High-Solids Silicone Roof Coating: MantaSil™ 430 Specs and Approvals

MantaSil™ 430 is a single-component, high-solids silicone roof coating from Manta Roofing Products. It moisture-cures and bonds to the roof surface, stands up to ponding water, and reflects sunlight to help keep the building cooler. It contains no solvent (VOC <50 g/L) and goes on by spray, roller or brush.

Technical data

Property Test method MantaSil™ 430
Solids by weight ASTM D2369 97% ± 2%
Weight per gallon at 77°F — 11.15 ± 0.2 lb/gal (1.34 kg/L)
VOC — <50 g/L
Initial elongation ASTM D2370 298%
Initial tensile strength ASTM D2370 309 psi
Tear resistance ASTM D624 23.3 lbf/in
Permeability ASTM E96 4.94 perms
Accelerated weathering ASTM D4798 5,000 hours; elongation after aging passes ASTM D6694
Tack-free / recoat / full cure — 2–4 h / 24 h at 100°F (38°C), 70% RH / more than 72 h at 70% RH
Application temperature — 65°F to 120°F (18.3°C to 49°C)
Maximum surface temperature — 180°F (82°C)
Colors — White, Light Gray, Gray, Tan, Safety Yellow
Packaging — 5 gal (18.9 L), about 58 lb gross; 55-gal drum (208.2 L), about 660 lb gross

Test values are typical, measured on laboratory samples; not specifications. Solids by weight and weight per gallon are plant quality-control targets.

Rate by warranty term (Manta system specifications)

A single coat of MantaSil™ 430 at the warranty-term rate:

Warranty term MantaSil™ 430 Dry film
10 years 1.5 gal/sq 22 mil
15 years 2.0 gal/sq 30 mil
20 years 2.5 gal/sq 37.5 mil

Where granules are broadcast, they go into a second coat of MantaSil™ 430 at ½ to ¾ gal/sq, on top of the warranty-rate coat.

Approvals and listings

  • Miami-Dade County Notice of Acceptance: NOA 25-0930.01 (expires 06/19/2030)
  • State of Florida Approved: FL #48102, Model 48102.5
  • UL 790 Class A fire rating: UL File R41576; listed assemblies in UL Product iQ. Also UL 790 Class A as MantaSil™ 430 over MantaSPF™ InstaShield 250™ spray foam (non-combustible deck).
  • Cool Roof Rating Council (CRRC): Product ID 1458-0001 (White): solar reflectance 0.87 initial / 0.76 aged; thermal emittance 0.90 / 0.90; SRI 110 / 94.

Frequently asked questions

What are the solids of MantaSil™ 430? 97% ± 2% solids by weight (ASTM D2369).

What is the VOC of MantaSil™ 430? Less than 50 g/L. MantaSil™ 430 contains no solvent.

How much MantaSil™ 430 do I apply? A single coat of MantaSil™ 430 at the warranty-term rate in the Manta system specification: 1.5 gal/sq for 10 years, 2.0 gal/sq for 15 years and 2.5 gal/sq for 20 years.

Which approvals does MantaSil™ 430 carry? Miami-Dade NOA 25-0930.01, Florida Product Approval FL #48102 (Model 48102.5), a UL 790 Class A fire rating (UL File R41576) and CRRC Product ID 1458-0001 for White.

Which roofs can MantaSil™ 430 go on? Aged BUR and modified-bitumen roofs; aged TPO, EPDM and PVC single-ply; SPF roofs; metal or concrete roofs; and existing coatings (recoat). Use MantaPrime™ 230 Bleed Block Primer over BUR and modified bitumen, and MantaPrime™ 235 on rusty metal.